SOLUTION: Thick finishes.
CYCLE |
INDICATIVE QUANTITY OF MATERIAL PER SQM
|
|
In the presence of mold, preventive treatment by applying a solution of BIOCID and leaving it to act for at least 24 hours.
|
|
|
If it is necessary to completely remove old paints and/or coatings, strip with paint stripper. High-pressure hydroclean, brush or scrape the entire facade, cleaning it from any flaking paint or peeling off, eliminating any dirt or dust. Make any plaster repairs and/or caulking with materials compatible with existing ones.
|
|
Apply a coat of FIXACRIL water-based penetrating fixative properly diluted.
|
|
|
Apply a coat of consolidating primer based on styrene acrylic solvent ISOMUR in case of particularly flaking, poorly cohesive or stripped supports.
|
|
|
If very irregular, shave with MINERALCIVIL universal white fibrous smoothing finish and let it season for 10 days.
|
1.25 KG/SQM PER MM OF THICKNESS
|
|
Apply a coat of diluted PIGMENTED FIXACRIL or PREVENTIVE FUND PIGMENTED (ready to use).
|
|
|
Spatula application of exterior plaster coating with a scraped effect, light-resistant pigments, CLASS COAT or CLASS COAT PREVENT (resistant to mold and algae growth), in versions 120/150.
|
2.0 . 2.5 KG/SQM. (120) 2.5 . 3.0 KG/SQM. (150)
|
|
Spatula application of external plaster coating with a scraped effect, light-resistant pigments, LAMATO COAT or LAMATO COAT PREVENT, (resistant to mold and algae growth), in versions 100/120/150.
|
1.8 - 2.2 KG/SQM. (100) 2.0 . 2.5 KG/SQM. (120) 2.5 . 3.0 KG/SQM. (150)
|
|
Spatula application of GRAF COAT 180, continuous scraping effect wall coating.
|
|